Products
Products
Name: Type CSZ water power axial flow fans for marine or navy use

CSZ series fan have high anti-hazard classification, sound anti-wobble, anti-vibration and anti-impact performance. The fan simple structure. Low weight, simplicity of operation as well as its port-ability ( normally only one operator required ) ,drive

Product Introduction:

1.Fan structure
CSZ Series ventilator fan composed of water turbine frame, casing, rotor and impeller, the water turbine precisely cast of anti-corrosion copper alloy and the casing welding of austenitic stainless steel, the impeller cast of high strength sealing a aluminum alloy. The water turbine and the rotor adopt two degrees of sealing, contact sealing and padding A safety brass ring fitted between the casing and impeller, with the structure of no-spark design CSZ ventilator fan serve either supply or exhaust fan, but they can’t displace use.
2.Fan applicable conditions
For palaces where there are explosive grade IIB and IIC and group from T4 to T6.
Ambient temperatures: -25℃~55℃
Relative humidity of the air: ≤95%
Cyclical vacillation: ±22.5℃~45℃
   Sustained horizontal tilting: ±15℃
   Sustained vertical tilting: ±10℃
   Vibration: existence
   Shock: existence

3. Model explanation

4. Use and maintenance
4.1 Before installing the fans, should check whether each part is intact, whether the components are complete, whether the impeller and casing rotating direct are concordant.
4.2When installing the duct of the inlet and outlet, should make the duct and fans be spontaneous identical, not join them forcing, not bring the weight of duct on the fans.
4.3After installed the fans, check whether there is friction of collide between the impeller and the fixed parts by rotating the impeller. If collision, friction, loud noise or strong vibration happened, the fan should be restart after checking. Avoid the fan being bumped and other substance or liquid entered the fans. Please clean the dust on blade of impeller in time, so as not to break the balance and strengthen the noise.
4.4The fans maintain must be done on stop working time. When burning, after check, should whether the every part of fans is normal.
4.5As some fault occurred in fans operating, should find out the reason in time and think a way of resolution.

型 号

Type

流 量   m3/h

Volume

静 压 Pa

Static press

进水压力M Pa

Water pressure

耗水量 m3/h

Water consumption

D1

D2

D3

D4

H

n-d

重量Weight

kg

CSZ-300

3000~6000

260~820

0.2~0.5

25~43

300

336

366

446

404

8-Ф11

30.5

CSZ-380

4000~10000

380~1020

0.2~0.5

28~53

380

416

446

546

546

8-Ф11

35


Inquire: